UP 2200

Item No. 5110030678
Frame mounted unit for desalination of softened drinking water operating on the principle of reverse osmosis (RO) in conjunction with the electro-deionization method (EDI).
This product cannot be ordered at the moment.
Description

Frame mounted unit for desalination of softened drinking water operating on the principle of reverse osmosis (RO) in conjunction with the electro-deionization method (EDI).

General
Features <li>Complete unit skid mounted</li><li>For the production of ultrapure water</li><li>Reverse osmosis combined with electro-deionization</li><li>RO 1000 controller</li><li>Recovery: 70%</li><li>Resistivity of UP water (with free CO2): 5MΩxcm</li><li>Design pressure: 12 to 18 bar (depending on type)</li><li>Voltage: 230 V/50 Hz (150 - 250) / 3 x 400 V/50 Hz (550 - 20000)</li><li>Analogue flow meters</li>
Good to know

For the production of ultrapure water with resistance >10MΩxcm

Footnotes

The units are designed for softened feed water (< 0.1 ° GH) with a maximum TDS of 1,000 mg/l, a water temperature of 15 °C, a maximum colloidal index of 3, a CO2 content of 10 mg/l and a SiO2 content of 20 mg/l. Under these conditions, the units still reach design product flow after three years of operation. The EDI product recovery depends on the raw water quality and the type of pre-treatment.

Specifications
Width 2530 mm
Height 2030 mm
Depth 850 mm
Weight 420 kg
Flow Rate 2200 l/h
Permeate Flow 2200 l/h
Membranes 4040 x 8
Ambient Temperature Max. 40°c
Voltage 3 x 400V / 50Hz
Power Consumption 7.1 kw
Controller RO 1000
Max Operating Pressure 16 bar
Recovery 70 %
Feedwater Connection DN32
Pre-fusing 20 A
Feedwater Pressure min./max. 2/6 bar
Feedwater Temperature min./max. 5/35 °c
pH Range 5 - 9.5
Waste Water Connection HT 50
Product Water Connection DN20
Resistivity EDI Product (With CO2) > 5 MΩ x cm
Resistivity EDI Product (Without CO2) > 10 MΩ x cm