UP 1500
Item No.
5110030676
Frame mounted unit for desalination of softened drinking water operating on the principle of reverse osmosis (RO) in conjunction with the electro-deionization method (EDI).
Description
Frame mounted unit for desalination of softened drinking water operating on the principle of reverse osmosis (RO) in conjunction with the electro-deionization method (EDI).
General
Features | <li>Complete unit skid mounted</li><li>For the production of ultrapure water</li><li>Reverse osmosis combined with electro-deionization</li><li>RO 1000 controller</li><li>Recovery: 70%</li><li>Resistivity of UP water (with free CO2): 5MΩxcm</li><li>Design pressure: 12 to 18 bar (depending on type)</li><li>Voltage: 230 V/50 Hz (150 - 250) / 3 x 400 V/50 Hz (550 - 20000)</li><li>Analogue flow meters</li> |
Good to know | For the production of ultrapure water with resistance >10MΩxcm |
Footnotes | The units are designed for softened feed water (< 0.1 ° GH) with a maximum TDS of 1,000 mg/l, a water temperature of 15 °C, a maximum colloidal index of 3, a CO2 content of 10 mg/l and a SiO2 content of 20 mg/l. Under these conditions, the units still reach design product flow after three years of operation. The EDI product recovery depends on the raw water quality and the type of pre-treatment. |
Specifications
Width | 2530 mm |
Height | 2030 mm |
Depth | 850 mm |
Weight | 320 kg |
Flow Rate | 1500 l/h |
Permeate Flow | 1500 l/h |
Membranes | 4040 x 6 |
Ambient Temperature | Max. 40°c |
Voltage | 3 x 400V / 50Hz |
Power Consumption | 4.1 kw |
Controller | RO 1000 |
Max Operating Pressure | 15 bar |
Recovery | 70 % |
Feedwater Connection | DN32 |
Pre-fusing | 20 A |
Feedwater Pressure | min./max. 2/6 bar |
Feedwater Temperature | min./max. 5/35 °c |
pH Range | 5 - 9.5 |
Waste Water Connection | HT 50 |
Product Water Connection | DN20 |
Resistivity EDI Product (With CO2) | > 5 MΩ x cm |
Resistivity EDI Product (Without CO2) | > 10 MΩ x cm |