UO-D 18000 AS
Item No.
5110050041
For desalination of hardness stabilised drinking water according to drinking water regulations (free chlorine not detectable).
Description
For desalination of hardness stabilised drinking water according to drinking water regulations (free chlorine not detectable).
General
Features | <li>Complete unit skid mounted</li><li>RO digital controller</li><li>Recovery from 75% to 80%</li><li>Salt rejection percentage: min. 97%</li><li>Voltage: 3 x 400V / 50 Hz</li><li>Design pressure: 11.5 to 13 bar (depending on type)</li><li>Digital flow meters</li><li>Profinet interface (option)</li><li>Incl. concentrate rinsing</li><li>Incl. connector kit for manual cleaning set</li><li>Prepared for a dosing station with antiscalant</li> |
Footnotes | The RO devices are designed for a maximum TDS content of 1000 mg/l, water temperature of 15°c and maximum SDI of 3. The return will depend on the incoming water and the type of pretreatement. |
Specifications
Width | 6190 mm |
Height | 1880 mm |
Depth | 840 mm |
Weight | 1300 kg |
Flow Rate | 18000 l/h |
Permeate Flow | 18000 l/h |
Membranes | 8040 x 15 |
Ambient Temperature | Max. 40°c |
Voltage | 3 x 400V / 50Hz |
Controller | RO digital |
Max Operating Pressure | 12 bar |
Recovery | 75 % |
Feedwater Connection | DN65 |
Permeate/Concentrate Connection | DN65/50 |
Motor Power | 15 kw |
Minimal Salt Rejection | 97 % |
Pre-fusing | 40 A |
Conductivity Range | 1 - 999 µS/cm |
Feedwater Pressure | min./max. 2/6 bar |
Feedwater Temperature | min./max. 5/35 °c |
pH Range | 3 - 11 |