UO-D 900
Item No.
5110010187
For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable).
Description
For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable).
General
Features | <li>Skid mounted, complete unit</li><li>Particularly space-saving (610 x 810 x 1800 mm)</li><li>RO digital controller</li><li>Recovery from 75% to 80%</li><li>Salt rejection percentage: 97%</li><li>Working pressure: 14 bar</li><li>Voltage: 3 x 400V / 50 Hz</li><li>Digital flow meters</li> |
Footnotes | The units are designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a max. colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after 3 years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment. |
Specifications
Width | 605 mm |
Height | 1810 mm |
Depth | 810 mm |
Weight | 160 kg |
Permeate Flow | 900 l/h |
Membranes | 4040 x 3 |
Ambient Temperature | Max. 40°c |
Voltage | 3 x 400V / 50Hz |
Controller | RO digital |
Max Operating Pressure | 14 bar |
Recovery | 75 - 80 % |
Feedwater Connection | DN20 |
Permeate/Concentrate Connection | DN20/15 |
Motor Power | 1.5 kw |
Minimal Salt Rejection | 97 % |
Pre-fusing | 20 A |
Conductivity Range | 1 - 999 µS/cm |
Feedwater Pressure | min./max. 2/6 bar |
Feedwater Temperature | min./max. 5/35 °c |
pH Range | 3 - 11 |