UO-D 1200 FU

Item No. 5110010192
For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable). Up to 30% energy savings due to high pressure pump with frequency converter (FU) with control of permeate flow rate at constant value (PKR). Particularly quiet operation.
This product cannot be ordered at the moment.
Description

For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable).

Up to 30% energy savings due to high pressure pump with frequency converter (FU) with control of permeate flow rate at constant value (PKR). Particularly quiet operation.

General
Features <li>Skid mounted, complete unit</li><li>Particularly space-saving (610 x 810 x 1800 mm)</li><li>RO digital controller</li><li>Recovery from 75% to 80%</li><li>Salt rejection percentage: min. 97%</li><li>Working pressure: 14 bar</li><li>Digital flow meters</li>
Advantages

Advantages of the FU version:

  • Energy saving of 30 - 50 % compared to RO units without VSD
  • Automatic regulation PKR for constant permeate rates even at fluctuating operating conditions included
  • Particularly quiet operation
Footnotes

The unit is designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pretreatment.

Specifications
Width 605 mm
Height 1810 mm
Depth 810 mm
Weight 180 kg
Permeate Flow 1200 l/h
Membranes 4040 x 4
Ambient Temperature Max. 40°c
Voltage 3 x 400V / 50Hz
Controller RO digital
Max Operating Pressure 14 bar
Recovery 75 - 80 %
Feedwater Connection DN20
Permeate/Concentrate Connection DN20/15
Motor Power 2.2 kw
Minimal Salt Rejection 97 %
Pre-fusing 20 A
Conductivity Range 1 - 999 µS/cm
Feedwater Pressure min./max. 2/6 bar
Feedwater Temperature min./max. 5/35 °c
pH Range 3 - 11
    Loading