UO 10000 ND

Item No. 5110010007
For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable). Mounted on Stainless steel skid with horizontal membrane housing 8"
This product cannot be ordered at the moment.
Description

For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable). Mounted on Stainless steel skid with horizontal membrane housing 8"

General
Features <li>Complete unit skid mounted</li><li>RO 1000 controller</li><li>Recovery: up to 75%</li><li>Salt rejection percentage: 97%</li><li>Working pressure: 10 to 14 bar (depending on type)</li><li>Analogue flow meters</li>
Good to know

Highest desalinisation level, up to 99% and more

Footnotes

The unit is designed for a maximum TDS of 1,000 mg/l, a watertemperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment.

Specifications
Width 4900 mm
Height 1820 mm
Depth 790 mm
Weight 900 kg
Flow Rate 10000 l/h
Permeate Flow 10000 l/h
Membranes 8040 x 8
Ambient Temperature Max. 40°c
Voltage 3 x 400V / 50Hz
Controller RO 1000
Max Operating Pressure 13 bar
Feedwater Connection DN50
Permeate/Concentrate Connection DN50/32
Motor Power 11 kw
Minimal Salt Rejection 97 %
Pre-fusing 32 A
Conductivity Range 2 - 200 µS/cm
Feedwater Pressure min./max. 2/6 bar
Feedwater Temperature min./max. 5/35 °c
pH Range 3 - 11
    Loading