UO-D 500
Item No.
5110010177
For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable). Compact unit suitable for wall mounting or fixation on the floor.
Description
For desalination of softened drinking water according to drinking water regulations (free chlorine not detectable).
Compact unit suitable for wall mounting or fixation on the floor.
General
Features | <li>Wall mounted or free standing</li><li>Particularly space-saving (460 x 400 x 1260 mm)</li><li>RO digital controller</li><li>Recovery from 75% to 80%</li><li>Salt rejection percentage: min. 97%</li><li>Working pressure: 12 bar</li><li>Voltage: 230 V/50 Hz</li><li>Digital flow meters</li> |
Footnotes | The unit is designed for a maximum TDS of 1,000 mg/l, a water temperature of 15°C, a maximum colloidal index of 3 and free permeate outlet. Under these conditions, the unit still reaches design permeate flow after three years of operation. The permeate recovery depends on the raw water quality and the type of pre-treatment. |
Specifications
Width | 460 mm |
Height | 1260 mm |
Depth | 400 mm |
Weight | 70 kg |
Permeate Flow | 500 l/h |
Membranes | 4040 x 2 |
Ambient Temperature | Max. 40°c |
Voltage | 230V / 50Hz |
Controller | RO digital |
Max Operating Pressure | 12 bar |
Recovery | 75 - 80 % |
Feedwater Connection | DN20 |
Permeate/Concentrate Connection | DN10 |
Motor Power | 0.55 kw |
Minimal Salt Rejection | 97 % |
Pre-fusing | 16 A |
Conductivity Range | 1 - 999 µS/cm |
Feedwater Pressure | min./max. 2/6 bar |
Feedwater Temperature | min./max. 5/35 °c |
pH Range | 3 - 11 |