UO-D 20000 AS/FU
Reverse osmosis units for the desalination of hardness-stabilised water with a salinity of up to 1,000 mg/l. Operated with dosing of antiscale instead of upstream softening. Each unit is equipped with a high-quality centrifugal pump with variable-speed drive (VSD = FU), which reduces energy consumption by 30 - 50 % .
The RO digital microprocessor controller enables fully automatic operation with logging of all relevant operating data and freely adjustable limit values. The unit can be connected to the central control system via optional interfaces.
Features | <li>Complete unit skid mounted</li><li>RO digital controller</li><li>Recovery from 75% to 80%</li><li>Salt rejection percentage: min. 97%</li><li>Voltage: 3 x 380 - 400 or 500V / 50-60 Hz</li><li>Optional: Profinet, Profibus, Modbus RTU/TCP and BACnet interfaces</li><li>Optional: SPS (PLC Siemens S7-1200) instead of RO digital</li><li>Optional: PP version instead of PVC</li><li>Incl. connector kit for manual cleaning set</li><li>Incl. concentrate rinsing</li><li>Prepared for a dosing station with antiscalant</li> |
Advantages | Advantages of RO units with VSD (FU)
|
Footnotes | The RO devices are designed for a maximum TDS content of 1000 mg/l, water temperature of 15°c and maximum SDI of 3. The return will depend on the incoming water and the type of pretreatement. |
Width | 4990 mm |
Height | 2230 mm |
Depth | 840 mm |
Weight | 1500 kg |
Flow Rate | 20000 l/h |
Permeate Flow | 20000 l/h |
Membranes | 8040 x 17 |
Ambient Temperature | Max. 40°c |
Voltage | 3 x 400V / 50Hz |
Controller | RO digital |
Max Operating Pressure | 11.5 bar |
Recovery | 75 % |
Feedwater Connection | DN65 |
Permeate/Concentrate Connection | DN65/50 |
Motor Power | 15 kw |
Minimal Salt Rejection | 97 % |
Pre-fusing | 40 A |
Conductivity Range | 1 - 999 µS/cm |
Feedwater Pressure | min./max. 2/6 bar |
Feedwater Temperature | min./max. 5/35 °c |
pH Range | 3 - 11 |